Theory
The greater the base concentration a lot more quickly system is produced (rate of effect increases) until enzyme vividness is reached at which time more substrate has no further more effect. Enzymes such as Catalase are protein molecules which can be found in living cells. They can be used to increase specific reactions in the skin cells. They are all extremely specific since each chemical just functions one particular effect. Catalase is usually an enzyme found in food such as potato and lean meats. It is employed for removing Hydrogen Peroxide from your cells.
Hydrogen Peroxide is definitely the poisonous by-product of metabolic process. Catalase increases the decomposition of Hydrogen Peroxide in water and oxygen while shown inside the equations beneath.
It is able to improve the decomposition of Hydrogen Peroxide because the shape of its active web page matches the form of the Hydrogen Peroxide molecule. This type of response where a molecule is divided into smaller pieces is known as an anabolic reaction.
Hypothesis
The conjecture would be such that as the substrate attention increases, the speed of reaction will go up at a directly proportionate rate before the solution becomes saturated while using substrate hydrogen peroxide.
When this saturation stage is reached, then adding extra substrate will make not any difference.
The rate steadily improves when even more substrate is added because more of the effective sites from the enzyme are utilized which results in even more reactions hence the required quantity of oxygen is made quicker. Once the amount of base molecules added exceeds the amount of active sites available then simply
the rate of effect will no longer rise. This is because the utmost number of reactions are being done at once therefore any extra substrate molecules have to delay until some of the active sites provided.
Factors
- Independent Variable(s)
Attentiveness of substrate Centered Variable(s) Rate of enzyme activity Control Variable(s) Temperature pH Pressure 
- Device
- S. Zero
Item Qty. Size, Capacity, Volume you Managed to graduate cylinder 1 500mL, 500cm3 2 Metallic Stand 1 “ 3 Catalase from Chicken Liver organ 7 you gm each some Hydrogen Peroxide (2%-14%) 1 each 10 mL each 5 Test Tubes several “ six Evaluation Tube Tray 1 “ several Distilled water “ 1 L eight Stopwatch 1 “ 9 Pipette you twelve mL 10 Tub 1 2000mL 11 Cork with hole for transferring conduit six “ doze Copying tube 7 “ 13 Rubber conduit several 100cm 
Procedure
1. Add 1gm of chicken liver to one test tube. Add 10mL of hydrogen peroxide solution at a concentration of 2% to the other test tube. Use a pipette to measure out the volumes. It is very important to accurately measure the amounts of Hydrogen Peroxide and chicken liver to ensure a fair test. 2. Pour the hydrogen peroxide solution into the test tube containing the chicken liver and immediately put the cork with a transferring tube plugged into it connecting it to a rubber tube leading to a filled inverted graduated cylinder to measure the amount of gas in mL (cm3) formed. 3. Bubbles should start to rise up the tube and the water level in the graduated cylinder should move down. 4. Record the water level after every 30 seconds for a total period of 5 minutes. 5. Do the same for 4%, 6%, 8%, 10%, 12% and 14% and record the readings for them individually.
Results
- Conc. ->
2% 4% 6% 8% 10% 12% 14% Initial 82 108 55 sixty six seventy two seventy five eighty-five Following “ 
- 0. 50
84 122 74 130 130 119 107 1 . 00 86 150 103 195 167 172 137 1 . 50 88 165 143 240 242 222 167 2 . 00 91 185 one hundred fifty five 273 295 228 212 installment payments on your 50 93 225 204 297 347 233 225 3. 00 96 245 245 323 376 238 334 a few. 50 97 264 286 329 417 241 335 4. 00 99 277 297 332 420 245 372 some. 50 103 299 300 335 432 250 402 5. 00 106 302 304 335 440 253 429 
- Total displacement
twenty four 109 249 269 368 178 344 
All of the measurements taken are in cm3 pertaining to the amount of gas formed/the sum of enzyme acted upon.
Interpretation
When the attentiveness of Hydrogen Peroxide is usually increased, the pace of effect increases at a immediately proportional charge until the concentration of Hydrogen Peroxide extends to about 10%. If you twice the attention of Hydrogen Peroxide then a rate of reaction increases as well. If the concentration is definitely doubled from 8-16% the speed goes up via 1 . 65-2. 97 Cm3 Oxygen created per second, which is a rise of 1. almost eight times. I actually wouldexpect the interest rate to increase two times if the Hydrogen Peroxide concentration is increased two times since there are twice as a large number of substrate elements which can join onto the enzymes active sites. The main reason that the number is less than two times could be deposit to the fact that by 10% the Enzyme’s effective sites may well already be near being condensed with Hydrogen Peroxide. There may also be several experimental problem which causes the inaccuracies.
Following 10% the rise in the rate of reaction slows down. This is certainly shown by gradient in the graph still dropping. At this point almost all the lively sites are occupied hence the active sites are said to be saturated with Hydrogen Peroxide. Increasing the Hydrogen Peroxide Concentration following your point of saturation has been reached will never cause the rate of a reaction to go up anymore. All the active sites are utilized so any kind of extra Hydrogen Peroxide elements will have to wait until an active site becomes available.
The theoretical optimum rate of reaction is when every one of the sites are being used but in truth this assumptive maximum is never reached because not all the active sites are being used all the time. The base molecules require time to join onto the enzyme and leave it and so the maximum charge achieved is actually slightly under the theoretical maximum. The time taken to fit into and leave the active web page is the constraining factor in the pace of response.
Limitations
a) There is a moderate delay between pouring the Hydrogen Peroxide into the catalase, putting the bung as well as starting the stopwatch. This will likely slightly have an effect on all the effects but as My spouse and i carried out all the three steps in the same manner for all the tests it should certainly not make any difference for the overall effect.
b) It is also impossible to precisely assess out the levels of Hydrogen Peroxide and catalase each time. While the scale for the pipettes displays the volume for the nearest mm3 the volume with the solutions which i used should be correct towards the nearest mm3. The volume of gas inside the test tube to start with is usually slightly affected by the amount that this bung will be shifted down each time, if the bung is pushed down further then your volume in the tube will probably be less hence the 30cm3 of gas can be reached faster.
c) Because of the fairly slower speedof our reactions it is just possible to measure the moments of the reaction to the nearest 0. 1 second even though the stopwatch shows the measurements to the nearest zero. 01 second.
d) Man errors including inappropriate blood pressure measurements, time difference in blood pressure measurements, stopping circulation of air by unintentionally compressing plastic tube¦ could also have been manufactured.
1

